<?xml version="1.0" encoding="iso-8859-1" ?>
<feed version="0.3" xmlns="http://purl.org/atom/ns#" xmlns:dc="http://purl.org/dc/elements/1.1/">
<!--
	This feed generated for Anonymous	More info at http://naklon.info/rss/about.htm
-->
	<title>.:: WebFrio ::.</title>
	<generator>RSS Feed 2.2.4</generator>
	<link rel="alternate" type="text/html" href="http://www.webfrio.com/"/>
	<modified>2010-09-09T12:24:21Z</modified>
	<entry>
		<title mode="escaped">Equipos y Accesorios. :: RE: Tuercas reducidas</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1512#p1512"/>
		<dc:creator>joseb65</dc:creator>
		<dc:subject>Equipos y Accesorios.</dc:subject>
		<author>
		<name>joseb65</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1512#p1512</id>
		<issued>2010-09-09T11:53:36Z</issued>
		<modified>2010-09-09T11:53:36Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=4&quot; target=&quot;_blank&quot;&gt;joseb65&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: Tuercas Reducidas&lt;br /&gt;Publicado: Jueves, 09 Septiembre 2010, 11:53 AM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	hola bueno bamos a las tuercas, yo los equipos que he visto, vienen con su bolsa de tuercas etc las tuercas, al igual que el tubo, lo hacen otros fabricantes, barilla exagonal taladro rosca  refrentado  y hacen miles ,en tornos automaticos, o revolver, al igual que los obus, asi que para mi las tuercas son todas igual, salvo en refrigeracion  industrial que son de bronce, pero estas que vienen en los aparatos pequeños  son  de metal, en fabrica  hay cajas enteras de tuercas de obus etc , los mazos de cableado vienen de otras fabricas solo para conectar en montage, los presostatos tambien ,solamente se montan, en algunos casos se regulan en los ensayos , saludos&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Aire Acondicionado :: RE: AA Con Problemas De Congelacion En Tuberia.</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1511#p1511"/>
		<dc:creator>JOSE_CM</dc:creator>
		<dc:subject>Aire Acondicionado</dc:subject>
		<author>
		<name>JOSE_CM</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1511#p1511</id>
		<issued>2010-09-08T12:37:18Z</issued>
		<modified>2010-09-08T12:37:18Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=39&quot; target=&quot;_blank&quot;&gt;JOSE_CM&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: AA Con Problemas De Congelacion En Tuberia.&lt;br /&gt;Publicado: Miércoles, 08 Septiembre 2010, 12:37 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	hola javi,lo del circuito obstruido tb lo pense,pero en todo caso tendrian que ser en algunas de las dos partes de la maquina mas bien,o en el evaporador o condensador. aunque cuando la instale limpie bien circuiteria y buenos vacios.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
el manometro esta bien javi,sigo trabajando con el y me va perfecto para los demas trabajos,marca bien.&lt;br /&gt;
&lt;br /&gt;
efectivamente  tube que añadir un poco de refrigerante,aunque tampoco mucho.&lt;br /&gt;
&lt;br /&gt;
el tema de las fugas,seria la 1º vez que veo que por culpa de una fuga pudiera tener esas presiones tan altas,nunca me a pasado (pero podria entrar dentro de lo que dices javi,la descompensacion podria hacer eso ,aunque personalmente veo esto poco probable)&lt;br /&gt;
&lt;br /&gt;
y yo las dos posibilidades que mas probables podrian dar este problema ,son ,la valvula de 4 via o compresor.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
la cuestion es que la maquina a estado mas de año y medio funcionando correctamente,pero con un rendimiento  un poco por debajo de lo normal desde que se instalo.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
por este motivo  tan raro comente esta averia,porque vosotros teneis muchisima mas experiencia y quizas ya os a pasado alguna vez.&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Electricidad :: &lt;&lt;**CONEXIONES CARRIER YORK **&lt;&lt;</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1510#p1510"/>
		<dc:creator>joseb65</dc:creator>
		<dc:subject>Electricidad</dc:subject>
		<author>
		<name>joseb65</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1510#p1510</id>
		<issued>2010-09-08T10:02:15Z</issued>
		<modified>2010-09-08T10:02:15Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=4&quot; target=&quot;_blank&quot;&gt;joseb65&lt;/a&gt;&lt;br /&gt;
	Asunto: &amp;lt;&amp;lt;**CONEXIONES CARRIER YORK **&amp;lt;&amp;lt;&lt;br /&gt;Publicado: Miércoles, 08 Septiembre 2010, 10:02 AM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	&amp;lt;&amp;lt; CONEXIONES COMPRESORES CARRIER YORK CHRYSLER DUNHANM-BUSH TRANE COPELAND  &amp;lt;&amp;lt;&lt;br /&gt;
&lt;br /&gt;
  &lt;a class=&quot;post-url&quot; href=&quot;http://www.brainerdcompressor.com/_pdf_files/Compressor_Wireing_Diagrams.pdf&quot; target=&quot;_blank&quot;&gt;http://www.brainerdcompressor.com/_...ng_Diagrams.pdf&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Electricidad :: &lt;&lt;**CONEXIONES CARRIER YORK **&lt;&lt;</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1509#p1509"/>
		<dc:creator>joseb65</dc:creator>
		<dc:subject>Electricidad</dc:subject>
		<author>
		<name>joseb65</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1509#p1509</id>
		<issued>2010-09-08T10:02:15Z</issued>
		<modified>2010-09-08T10:02:15Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=4&quot; target=&quot;_blank&quot;&gt;joseb65&lt;/a&gt;&lt;br /&gt;
	Asunto: &amp;lt;&amp;lt;**CONEXIONES CARRIER YORK **&amp;lt;&amp;lt;&lt;br /&gt;Publicado: Miércoles, 08 Septiembre 2010, 10:02 AM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	&amp;lt;&amp;lt; CONEXIONES COMPRESORES CARRIER YORK CHRYSLER DUHAN &amp;lt;&amp;lt;&lt;br /&gt;
&lt;br /&gt;
  &lt;a class=&quot;post-url&quot; href=&quot;http://www.brainerdcompressor.com/_pdf_files/Compressor_Wireing_Diagrams.pdf&quot; target=&quot;_blank&quot;&gt;http://www.brainerdcompressor.com/_...ng_Diagrams.pdf&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped"> Normativas :: RE: R. D. 795/2010 Sobre La Comercialización De Gases Fluorados</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1508#p1508"/>
		<dc:creator>Javigod</dc:creator>
		<dc:subject> Normativas</dc:subject>
		<author>
		<name>Javigod</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1508#p1508</id>
		<issued>2010-09-08T08:02:45Z</issued>
		<modified>2010-09-08T08:02:45Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=3&quot; target=&quot;_blank&quot;&gt;Javigod&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: R. D. 795/2010 Sobre La Comercialización De Gases Fluora&lt;br /&gt;Publicado: Miércoles, 08 Septiembre 2010, 08:02 AM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	Bueno, pues acabo de enviar un correo a la delegacion de innovacion, ciencia y empresa de la Junta de Andalucia solicitando informacion sobre este tema.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
En cuanto me den informacion os la hago saber, aunque no me extrañaria que me dijeran que no saben nada o que los cursos de habilitacion se hacen en Nepal.&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Aire Acondicionado :: RE: AA Con Problemas De Congelacion En Tuberia.</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1507#p1507"/>
		<dc:creator>Javigod</dc:creator>
		<dc:subject>Aire Acondicionado</dc:subject>
		<author>
		<name>Javigod</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1507#p1507</id>
		<issued>2010-09-07T23:08:33Z</issued>
		<modified>2010-09-07T23:08:33Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=3&quot; target=&quot;_blank&quot;&gt;Javigod&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: AA Con Problemas De Congelacion En Tuberia.&lt;br /&gt;Publicado: Martes, 07 Septiembre 2010, 11:08 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	La verdad es que este tema es extraño...&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
¿Has comprobado que el manometro este en buen estado? No seria la primera vez que un tecnico se vuelve loco por un manometro defectuoso.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Por otro lado... si el compresor suena mal, como forzado... es probable que no de mas de si, mas aun cuando ha estado trabajando con tuberias mas pequeñas que las que necesita, y con una larga tirada de lineas frigorificas.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Hablamos de una presion en baja de 8 bares, con R-407c... un autentico pasote!!! ¿Has comprobado si hay alguna fuga? La mezcla puede estar descompensada, y la lectura del manometro se ve condicionada por esto.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
En su dia imagino que hubo que añadir mas refrigerante, debido a la linea tan larga.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Tambien puedes tener el circuito obstruido.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Sinceramente me inclino por que el compresor este cascado, concretamente las valvulas. aunque sin estar delante de la maquina es probable que me equivoque, ya que hablamos de un caso un tanto extraño.&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Charla General :: RE: Mi mar de dudas particular</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1506#p1506"/>
		<dc:creator>Javigod</dc:creator>
		<dc:subject>Charla General</dc:subject>
		<author>
		<name>Javigod</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1506#p1506</id>
		<issued>2010-09-07T22:44:38Z</issued>
		<modified>2010-09-07T22:44:38Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=3&quot; target=&quot;_blank&quot;&gt;Javigod&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: Mi mar de dudas particular&lt;br /&gt;Publicado: Martes, 07 Septiembre 2010, 10:44 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	Bueno... mi plan esta bastante maduro y te cuento un poco mas...&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
No tenia intencion de contratar a nadie, al menos en principio, pero en el caso de necesitarlo, seria por que habria volumen de trabajo y me interesaria.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Mi primo es Tec. Sup. en LPRL, y aunque no ejerce en esta profesion, siempre podria contar con el, ya sea contratandolo o con algun contacto suyo. Pero como me dices, no es necesario para mi solo, y lo de meterme en trabajos grandes, en principio pienso que no puedo asumirlos.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Tampoco iba a contar con local (en principio) y si iba a contar con pagina web, y una campaña de publicidad grande, basada en tripticos, por lo que ninguna empresa externa deberia inspeccionar mi local, ya que no hay.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Tengo mi compñaero de fatigas, el de toda la vida... y si todo fuera bien, el se haria autonomo tambien, al menos al principio, por lo que no seria contratado realmente, y creo que tampoco necesitaria este servicio.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
La verdad es que me planteo todo esto para el 1 de abril, asi que tengo tiempo para madurarlo mas. &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
PD: Gracias por hacerme ver lo que se me pueda pasar.&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Charla General :: RE: Mi mar de dudas particular</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1505#p1505"/>
		<dc:creator>Pascalin</dc:creator>
		<dc:subject>Charla General</dc:subject>
		<author>
		<name>Pascalin</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1505#p1505</id>
		<issued>2010-09-07T20:48:12Z</issued>
		<modified>2010-09-07T20:48:12Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=501&quot; target=&quot;_blank&quot;&gt;Pascalin&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: Mi Mar De Dudas Particular&lt;br /&gt;Publicado: Martes, 07 Septiembre 2010, 08:48 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	Hola Javigod: no vas mal encaminado, sino tienes en cuenta los gastos diarios de Gasolina, imprenta, dietas (si no comes en casa en algún lugar comerás ¿digo yo?), etc.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
De todas formas, si que se nos ha pasado algo fundamental (si quieres cumplir la ley a RAJATABLA), es la PREVENCIÓN DE RIESGOS LABORALES, tienes que contratar, un servicio de prevención de riesgos laborales ajeno.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Las Empresas con más de 25 trabajadores tienen que tener un técnico en prevención de riesgos laborales en plantilla, que es el responsable de que se cumpla la ley, controlar que existan planes de seguridad etc.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
En este caso como eres tú solo, no te lo exige, pero sí, que contrates con una empresa ajena que es la que se encargara de inspeccionarte tu local, tus obras si se lo comunicas y decirte lo que tienes que hacer o tener para cumplir la ley (encima que les pagas te sacan las pegas y A COMPRAR MAS), como señalizaciones , extintores, y la parafernalia de EPIS (Equipos de Protección Individual de Seguridad), también tienes que hacer los cursos de ellos, de prevención de riesgos laborales (estos están incluidos en la cuota anual) y las revisiones medicas anuales (que a mí me cuestan 50 € por persona).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Al ser tu solo, puedes pensar que si pasa algo, tú no te vas a denunciar a ti mismo, ni te vas a quejar al del espejo cuando lo ves, pero si te sale algún trabajo “apetitoso” de alguna Empresa constructora, promotora etc. (SOLVENTE), te lo pueden pedir y no adjudicártelo, si no cumples, y si encima has empezado el trabajo y te lo piden, EMPEZAMOS CON LAS PRISAS Y FOLLONES, también te lo puede pedir un particular. Para tu información a mi me cuesta 600 € anuales.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
En caso de que contrates a alguien para que te eche una mano, IMPRESCINDIBLE, no quiero pensar lo que te puede suceder si pasa alguna desgracia (Dios no quiera, yo hasta ahora no he tenido que comprobarlo afortunadamente).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Bueno, no es mi intención, de que cada vez que escribo algo sobre este tema, es para “ponerlo más crudo”, LAS COSAS ESTÁN ASÍ,  ¡¡¡¡¡¡¡¡¡¡¡¡¡¡ANIMOOOOOOOOOOOO!!!!!!!!!!!!!!!!!!.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Un saludo.&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Videos :: &lt;&lt;** VIDEO COMPRESORES BOCK **&lt;&lt;</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1504#p1504"/>
		<dc:creator>joseb65</dc:creator>
		<dc:subject>Videos</dc:subject>
		<author>
		<name>joseb65</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1504#p1504</id>
		<issued>2010-09-07T18:56:41Z</issued>
		<modified>2010-09-07T18:56:41Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=4&quot; target=&quot;_blank&quot;&gt;joseb65&lt;/a&gt;&lt;br /&gt;
	Asunto: &amp;lt;&amp;lt;** VIDEO COMPRESORES BOCK **&amp;lt;&amp;lt;&lt;br /&gt;Publicado: Martes, 07 Septiembre 2010, 06:56 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	&amp;lt;&amp;lt;VIDEO COMPRESORES BOCK   &amp;lt;&amp;lt; &lt;br /&gt;
&lt;br /&gt;
 &lt;object width=&quot;425&quot; height=&quot;350&quot;&gt;&lt;param name=&quot;movie&quot; value=&quot;http://www.youtube.com/v/XFzHQO9RzxY&amp;amp;NR&quot; /&gt;&lt;embed src=&quot;http://www.youtube.com/v/XFzHQO9RzxY&amp;amp;NR&quot; type=&quot;application/x-shockwave-flash&quot; width=&quot;425&quot; height=&quot;350&quot;&gt;&lt;/embed&gt;&lt;/object&gt;&lt;br /&gt;&lt;a href=&quot;http://youtube.com/watch?v=XFzHQO9RzxY&amp;amp;NR&quot; target=&quot;_blank&quot;&gt;Link&lt;/a&gt;&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Electricidad :: &lt;&lt;** CONEXIONES ELECTRICAS COMPRESORES CARRIER **&lt;&amp;</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1503#p1503"/>
		<dc:creator>joseb65</dc:creator>
		<dc:subject>Electricidad</dc:subject>
		<author>
		<name>joseb65</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1503#p1503</id>
		<issued>2010-09-07T18:09:52Z</issued>
		<modified>2010-09-07T18:09:52Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=4&quot; target=&quot;_blank&quot;&gt;joseb65&lt;/a&gt;&lt;br /&gt;
	Asunto: &amp;lt;&amp;lt;** CONEXIONES ELECTRICAS COMPRESORES CARRIER **&amp;lt;&amp;&lt;br /&gt;Publicado: Martes, 07 Septiembre 2010, 06:09 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	&amp;lt;&amp;lt; CONEXIONES  COMPRESORES  CARRIER&amp;lt;&amp;lt;  &lt;br /&gt;
&lt;br /&gt;
   &lt;a class=&quot;post-url&quot; href=&quot;http://www.dallashermetic.com/pdffiles/Carrier06ETerminalDiagrams.PDF&quot; target=&quot;_blank&quot;&gt;http://www.dallashermetic.com/pdffi...nalDiagrams.PDF&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Manuales :: **&lt;&lt; CALCULADORA FRIGORIFICA CAMARAS&lt;&lt;**</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1502#p1502"/>
		<dc:creator>joseb65</dc:creator>
		<dc:subject>Manuales</dc:subject>
		<author>
		<name>joseb65</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1502#p1502</id>
		<issued>2010-09-07T18:00:32Z</issued>
		<modified>2010-09-07T18:00:32Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=4&quot; target=&quot;_blank&quot;&gt;joseb65&lt;/a&gt;&lt;br /&gt;
	Asunto: **&amp;lt;&amp;lt; CALCULADORA FRIGORIFICA CAMARAS&amp;lt;&amp;lt;**&lt;br /&gt;Publicado: Martes, 07 Septiembre 2010, 06:00 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	&amp;lt;&amp;lt;CALCULADORA FRIGORIFICA  CAMARAS &amp;lt;&amp;lt;&lt;br /&gt;
&lt;br /&gt;
   &lt;a class=&quot;post-url&quot; href=&quot;http://www.beijeriberica.es/flash/calculadora_frigorifica.swf&quot; target=&quot;_blank&quot;&gt;http://www.beijeriberica.es/flash/calculadora_frigorifica.swf&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Manuales :: **&lt;&lt;COMPRESORES HERMETICOS BAJA MEDIA  ALTA TEMP LÙNIT</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1501#p1501"/>
		<dc:creator>joseb65</dc:creator>
		<dc:subject>Manuales</dc:subject>
		<author>
		<name>joseb65</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1501#p1501</id>
		<issued>2010-09-07T17:31:45Z</issued>
		<modified>2010-09-07T17:31:45Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=4&quot; target=&quot;_blank&quot;&gt;joseb65&lt;/a&gt;&lt;br /&gt;
	Asunto: **&amp;lt;&amp;lt;COMPRESORES HERMETICOS BAJA MEDIA  ALTA TEMP LÙNIT&lt;br /&gt;Publicado: Martes, 07 Septiembre 2010, 05:31 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	&amp;lt;&amp;lt; COMPRESORES    LUNITE  HERMETICA BAJA MEDIA ALTA TEMP &amp;lt;&amp;lt;&lt;br /&gt;
&lt;br /&gt;
  &lt;a class=&quot;post-url&quot; href=&quot;http://www.pecomark.com/PDF/ES/A1.PDF&quot; target=&quot;_blank&quot;&gt;http://www.pecomark.com/PDF/ES/A1.PDF&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Aire Acondicionado :: RE: AA Con Problemas De Congelacion En Tuberia.</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1500#p1500"/>
		<dc:creator>JOSE_CM</dc:creator>
		<dc:subject>Aire Acondicionado</dc:subject>
		<author>
		<name>JOSE_CM</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1500#p1500</id>
		<issued>2010-09-07T12:41:13Z</issued>
		<modified>2010-09-07T12:41:13Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=39&quot; target=&quot;_blank&quot;&gt;JOSE_CM&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: AA Con Problemas De Congelacion En Tuberia.&lt;br /&gt;Publicado: Martes, 07 Septiembre 2010, 12:41 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	haber joseb no se si me e explicado mal,pero voy a hacerlo de forma mas natural.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
en la condensadora estan las llaves y las dos conexiones para las tuberias, las de 1/4 (LA FINA) y la de 1/2 (LA GORDA)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
pues bien ,la tuberia mas gorda estaba totalmente  congelada (no  la fina que en este caso seria falta de refrigerante) repito fue la gorda. &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
CHEQUE LO SIGUIENTE:&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
ventilador del evaporador (correcto gran potencia de ventilacion)&lt;br /&gt;
&lt;br /&gt;
filtros del evaporador (totalmente limpios)&lt;br /&gt;
&lt;br /&gt;
ventilador de la condensadora (correcto)&lt;br /&gt;
&lt;br /&gt;
presion en tuberia gorda (la de 1/2) que lleva la valvula de servicio en la condensadora, presion por encima de 8 bares (muy alta para gas r407)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
el compresor trabajaba muy forzado con bajas revoluciones ,como ahogado ( se comprobo que el  voltaje de alimentacion era  correcto)&lt;br /&gt;
&lt;br /&gt;
cuando le recoji el gas a la maquina para desmontarla,el manometro  no me bajo de 0,5 bares,el compresor no me recojio mas efrigerante,cosa que me extraño porque siempre me baja por debajo de 0 (cero) asi que ese 0,5 bar  se quedo en la instalacion y se perdio.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
y para seguir con este tema,recordaros que la maquina estaba instalada en una instalacion con tuberias que no les correspondia, pues la maquina deveria utilizar en su instalacion  tuberia de 1/2 y se instalo y monto con tuberias de 3/8,con su consecuente reduccion de diametro y una tirada entre condensadora y evaporador de unos 16 metros.&lt;br /&gt;
&lt;br /&gt;
las tuberias de 1/4 coincidian como es normal.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
que pensais que pudo ser?&lt;br /&gt;
&lt;br /&gt;
se me ocurre problema en valvula de 4 vias como dice joseb&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Manuales :: &lt;&lt;REGLA ENTALPICA&lt;&lt;</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1499#p1499"/>
		<dc:creator>joseb65</dc:creator>
		<dc:subject>Manuales</dc:subject>
		<author>
		<name>joseb65</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1499#p1499</id>
		<issued>2010-09-07T11:18:02Z</issued>
		<modified>2010-09-07T11:18:02Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=4&quot; target=&quot;_blank&quot;&gt;joseb65&lt;/a&gt;&lt;br /&gt;
	Asunto: &amp;lt;&amp;lt;REGLA ENTALPICA&amp;lt;&amp;lt;&lt;br /&gt;Publicado: Martes, 07 Septiembre 2010, 11:18 AM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	&amp;lt;&amp;lt;    regla entalpica   &amp;lt;&amp;lt;   REGLA ENTALPICA&amp;lt;&amp;lt;&lt;br /&gt;
&lt;br /&gt;
  &lt;a class=&quot;post-url&quot; href=&quot;http://www.beijeriberica.es/flash/diagrama_entalpico.swf&quot; target=&quot;_blank&quot;&gt;http://www.beijeriberica.es/flash/diagrama_entalpico.swf&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Aire Acondicionado :: RE: AA Con Problemas De Congelacion En Tuberia.</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1498#p1498"/>
		<dc:creator>joseb65</dc:creator>
		<dc:subject>Aire Acondicionado</dc:subject>
		<author>
		<name>joseb65</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1498#p1498</id>
		<issued>2010-09-07T10:43:38Z</issued>
		<modified>2010-09-07T10:43:38Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=4&quot; target=&quot;_blank&quot;&gt;joseb65&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: AA Con Problemas De Congelacion En Tuberia.&lt;br /&gt;Publicado: Martes, 07 Septiembre 2010, 10:43 AM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	jose no entiendo lo del tubo de 1/2 si es de baja o aspiracion, como dices que me fuy a la condensadora y el tubo de 1/2 estaba  congelado, esto en el condensador no entiendo, si es tubo de aspiracion seria de evaporador a compresor&lt;br /&gt;
&lt;br /&gt;
 saludos&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
   maquina en frio, presiones altas exceso de refrigerant, falta de aire en condensador, incondensables en el circuito,ventilador parado,bajo de revoluciones,&lt;br /&gt;
&lt;br /&gt;
 presiones de baja alta, bajo rendimientocompresor o val inv  mal, saludos&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Aire Acondicionado :: RE: AA Con Problemas De Congelacion En Tuberia.</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1497#p1497"/>
		<dc:creator>joseb65</dc:creator>
		<dc:subject>Aire Acondicionado</dc:subject>
		<author>
		<name>joseb65</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1497#p1497</id>
		<issued>2010-09-07T10:15:41Z</issued>
		<modified>2010-09-07T10:15:41Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=4&quot; target=&quot;_blank&quot;&gt;joseb65&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: AA Con Problemas De Congelacion En Tuberia.&lt;br /&gt;Publicado: Martes, 07 Septiembre 2010, 10:15 AM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	hola jose  si esta por debajo de 0ºc hace hielo falta gas&lt;br /&gt;
&lt;br /&gt;
  si se congela la bateria evap  falta de gas&lt;br /&gt;
&lt;br /&gt;
  hace escarcha en el tubo de baja filtro sucio y bateria&lt;br /&gt;
&lt;br /&gt;
  si la tuberia de baja se congela falta gas&lt;br /&gt;
&lt;br /&gt;
  si esta fria o muy fria esta bien sise congela falta gas&lt;br /&gt;
&lt;br /&gt;
  tira agua como de lluvia  con el aire limpiar bateria&lt;br /&gt;
&lt;br /&gt;
  bajo consumo falta gas  saludos&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped"> Normativas :: Real Decreto 560/2010 Acceso A Las Actividades De Servicios</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1496#p1496"/>
		<dc:creator>gota</dc:creator>
		<dc:subject> Normativas</dc:subject>
		<author>
		<name>gota</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1496#p1496</id>
		<issued>2010-09-07T06:16:47Z</issued>
		<modified>2010-09-07T06:16:47Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=496&quot; target=&quot;_blank&quot;&gt;gota&lt;/a&gt;&lt;br /&gt;
	Asunto: Real Decreto 560/2010 Acceso A Las Actividades De Servicios&lt;br /&gt;Publicado: Martes, 07 Septiembre 2010, 06:16 AM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	Real Decreto 560/2010, de 7 de mayo, por el que se modifican diversas normas reglamentarias en materia de seguridad industrial para adecuarlas a la Ley 17/2009, de 23 de noviembre, sobre el libre acceso a las actividades de servicios y su ejercicio, y a la Ley 25/2009, de 22 de diciembre, de modificación de diversas leyes para su adaptación a la Ley sobre el libre acceso a las actividades de servicios y su ejercicio:&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;a class=&quot;post-url&quot; href=&quot;http://www.boe.es/boe/dias/2010/05/22/pdfs/BOE-A-2010-8190.pdf&quot; target=&quot;_blank&quot;&gt;http://www.boe.es/boe/dias/2010/05/22/pdfs/BOE-A-2010-8190.pdf&lt;/a&gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Este real decreto modifica algunos reglamentos entre ellos el Reglamento de Seguridad para Plantas e instalaciones frigoríficas, paginas 44861 a 44865&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Corrección de errores (sin mucha importancia):&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;a class=&quot;post-url&quot; href=&quot;http://www.boe.es/boe/dias/2010/06/19/pdfs/BOE-A-2010-9716.pdf&quot; target=&quot;_blank&quot;&gt;http://www.boe.es/boe/dias/2010/06/19/pdfs/BOE-A-2010-9716.pdf&lt;/a&gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Saludos.&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Aire Acondicionado :: RE: AIRE SAMSUNG</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1495#p1495"/>
		<dc:creator>JOSE_CM</dc:creator>
		<dc:subject>Aire Acondicionado</dc:subject>
		<author>
		<name>JOSE_CM</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1495#p1495</id>
		<issued>2010-09-06T23:04:56Z</issued>
		<modified>2010-09-06T23:04:56Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=39&quot; target=&quot;_blank&quot;&gt;JOSE_CM&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: AIRE SAMSUNG&lt;br /&gt;Publicado: Lunes, 06 Septiembre 2010, 11:04 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	hola solo tengo estos de modelos SC PERO NO ES EL QUE TU BUSCAS,si quieres puedes probar haber que pasa,si estan los pilotos parpadeando no creo tengas nada que perder;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
SC 24TA1--------- 090000-1A023F &lt;br /&gt;
&lt;br /&gt;
SC 18TA1--------- 090000-1A00FB&lt;br /&gt;
&lt;br /&gt;
SC 18ZA1--------- 090000-1A021D &lt;br /&gt;
&lt;br /&gt;
SC 05ZZ8 ----------000000-17021d&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
y un modelo sh que tiene despues las mismas numeraciones,aqui te la dejo por si te pudiese valer de algo.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
SH12AWH AQ12WHWE 25 02 57 03 40&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Aire Acondicionado :: RE: Que debes conocer antes y despues de comprar un A/A</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1494#p1494"/>
		<dc:creator>JOSE_CM</dc:creator>
		<dc:subject>Aire Acondicionado</dc:subject>
		<author>
		<name>JOSE_CM</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1494#p1494</id>
		<issued>2010-09-06T22:40:50Z</issued>
		<modified>2010-09-06T22:40:50Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=39&quot; target=&quot;_blank&quot;&gt;JOSE_CM&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: Que Debes Conocer Antes Y Despues De Comprar Un A/A&lt;br /&gt;Publicado: Lunes, 06 Septiembre 2010, 10:40 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	pues si como me acabo de enterar eurofred lleva el servicio Hiyasu y Daitsu no aconsejo estas marcas.pues aqui en sevilla son realmente unos sinverguenzas,no venden ni un misero material ,la atencion para intentar comprar un repuesto es llamando  a un telefono 806,(hablo por experiencia)asi que cuando termines de hablar ya se a comido el beneficio de tu supesta reparacion,este problema lo tengo yo y cualquier autonomo ,no discriminan,,,en cuanto  a las mejores marcas anteriormente expuestas estoy de acuerdo,,pero son caras como ya se a dicho al  igual que los repuestos, al costar mas valen mas, y normalmente las placas y compresores son caros y normalmente un compresor en aire,poca gente lo cambia cuando se  rompe,por lo que pensandolo bien una marca barata y fiable podria ser mas rentable,pero tiene el inconveniente de ser normalmente mas ruidosas y con un poco de mayor consumo electrico, y ahora hablando en positivo ,tienen componentes de marcas en su interior,como puede ser craft y firline de los grandes almacenes,que en la mayoria de los casos los compresores son samsung y toshiba.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
yo tengo en mi local 2 craft y me an salido supersilenciosas (normalmente dan ruido de  plasticos) y una firline de 5 años (la del modelo split pequeño y compresor toshiba) y esta es que ni se escucha.,,,,,,,,en fin ,cada uno elija lo que mas le convenga !!!!&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Aire Acondicionado :: AA Con Problemas De Congelacion En Tuberia.</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1493#p1493"/>
		<dc:creator>JOSE_CM</dc:creator>
		<dc:subject>Aire Acondicionado</dc:subject>
		<author>
		<name>JOSE_CM</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1493#p1493</id>
		<issued>2010-09-06T22:20:05Z</issued>
		<modified>2010-09-06T22:20:05Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=39&quot; target=&quot;_blank&quot;&gt;JOSE_CM&lt;/a&gt;&lt;br /&gt;
	Asunto: AA Con Problemas De Congelacion En Tuberia.&lt;br /&gt;Publicado: Lunes, 06 Septiembre 2010, 10:20 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	hola a todos,este verano he cambiado  y desmantelado un aire acondicionado taurus de 3500 frigorias,este aparato lo monte hace  casi dos años, tube muchos problemas con el cliente  que era mas cazurro que un burro,la cuestion es que la maquina utilizaba tuberia de 1/4 y 1/2,,,,, el tio tenia preistalacion pero con tuberia de  1/4 y 3/8 y una distancia entre split y condensadora de unos 16 metros y una descompensacion de nivel de altura de unos 8 metros por lo menos,le dije que la maquina perderia mucho rendimiento por la reduccion de tuberias y esa distancia tan grande,al final quiso montara la maquina apesar de mi negativa  de no montarla,pero como el cliente siempre tiene razon  lo hice ,,la monte,,,la cuestion que este verano se le a empesado  a bajar mucho el poco rendimiento que  ya tenia tanto que casi echaba aire ambiente,me fuy para la condensadora y la tuberia de 1/2 estaba escarchada totalmente y la presion estaba sobre los 8 bares y pico, con 407,asi que estaba  muy alta,&lt;br /&gt;
&lt;br /&gt;
pense que estaria los filtro de la evaporadora atascados y sucios pero no fue asi,estaban limpios y el ventilador estaba echando buen chorro de aire al igual que el ventilador de la condensadora,y a todo esto el compresor trabajando como forzado y ahogado con el voltaje correcto en su alimentacion a 220,,,,,,al final convenci al cazurro  para que modificara la instalacion y con una maquina nueva porque  no queria correr mas problemas con esa maquina (por si se huviese dañado el compresor ). y al final me salio todo bien con una maquina nueva e instalacion  con pocos metros  de tuberia.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
os cuento esto porque me acordado y me gustaria comentaramos aque pudo ser devido el escarche y congelacion de la tuberia de aspiracion de 1/2 teniendo en cuenta que  la maquina estaba trabajando en modo frio. y los datos que ya  he dado anteriormente,saludos.&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Charla General :: RE: Mi mar de dudas particular</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1492#p1492"/>
		<dc:creator>Javigod</dc:creator>
		<dc:subject>Charla General</dc:subject>
		<author>
		<name>Javigod</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1492#p1492</id>
		<issued>2010-09-06T21:40:40Z</issued>
		<modified>2010-09-06T21:40:40Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=3&quot; target=&quot;_blank&quot;&gt;Javigod&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: Mi mar de dudas particular&lt;br /&gt;Publicado: Lunes, 06 Septiembre 2010, 09:40 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	Hombre, el tema en mi empresa es el siguiente...&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Cuando me hicieron la entrevista dije que mis intenciones era crear mi propia empresa, en principio como autonomo, y mas adelante veria que pasaba, a lo que me respondieron que legalmente no pueden impedirmelo, pero que no les hacia gracia.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
En mi contrato no tengo exclusividad.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Mi contrato con la empresa es para un servicio en un centro determinado, y estamos hablando de un mantenimiento gordo en un centro comercial. Algo que yo no podria asumir solo.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Los gastos fijos, si no me equivoco son unos 3.000 € anuales (12 cuotas de autonomo + gastos de asesoria) + IVA (depende siempre de lo que factures) + 540 ( Seg. Resp. Civil con poliza de 312.000 € con Mapfre) y no se si se me escapa algo.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Si no se me escapa nada, para empezar necesito como minimo para los primeros 4 meses unos 1500 €.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Corregidme si me equivoco.&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Charla General :: RE: Mi mar de dudas particular</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1491#p1491"/>
		<dc:creator>Pascalin</dc:creator>
		<dc:subject>Charla General</dc:subject>
		<author>
		<name>Pascalin</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1491#p1491</id>
		<issued>2010-09-06T21:11:35Z</issued>
		<modified>2010-09-06T21:11:35Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=501&quot; target=&quot;_blank&quot;&gt;Pascalin&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: Mi Mar De Dudas Particular&lt;br /&gt;Publicado: Lunes, 06 Septiembre 2010, 09:11 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	Hola Javigod: Los datos son fundamentales para precisar las respuestas.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
La relación de acciones que menciono son genéricas para hacerse una idea, sin embargo tu situación es un caso especifico.&lt;br /&gt;
&lt;br /&gt;
Si la actividad que quieres desarrollar, NO AFECTA A LA CARTERA DE CLIENTES DE TU EMPRESA, es un problemón que te quitas de encima, puesto que puedes compaginar ambas cosas, y si ya tienes los carnet das un paso grande.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Legalmente lo puedes hacer, HACIENDA no tiene ningún inconveniente en que tu desarrolles 1,2,3 etc. actividades, más recaudan, la SEGURIDAD SOCIAL, tampoco y si estas cotizando en otras empresas, más recaudan (esto sí es, pura y dura recaudación de impuestos sin importarles nada), puedes hacer facturas y llevar la contabilidad oficial sin problema legales.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Al tener los carnets, de instalador y mantenedor, (que por sí solos no te sirven de nada, si no es en el seno de una empres habilitada), ya puedes ir a INDUSTRIA, con tus carnets, con tu alta de autónomo, alta en hacienda, tu seguro de responsabilidad civil, tu relación de herramienta para ejercer la actividad y al estar las competencias traspasadas a las comunidades autónomas, lo más seguro es que te falte algún papel más (de todas formas en las gestorías están o deberían de estar informados de los papeles necesarios y las nuevas disposiciones de carácter local y autonómico , como pueden ser las nuevas normativas de gases fluorados etc.).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Es importante que la actividad que desarrolles, no afecte a los clientes, de la Empresa en la cual estas trabajando (si vas a compaginar las dos), porque lo podrían considerar, deslealtad, apropiación de información etc. y las empresas que se aprecien, disponen de un bufete de abogados que están locos por ganar puntos y te machacarían sin piedad. SI LA EMPRESA CONOCE TUS INTENCIONES Y LAS APRUEBA, ADELANTE.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Ya solo falta, que valores los nuevos gastos fijos que adquieres con la seguridad social y seguro de responsabilidad civil, mientras obtienes las autorizaciones de industria y en ese preciso momento, que las tengas, ya puedes COMPRAR GAS LEGALMENTE (HOY POR HOY).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Que quede bien claro, que todo lo que estoy diciendo es propia experiencia y en una comunidad autónoma diferente y no por conocimientos de las normativas, insisto que las gestorías son la mejor forma de encauzar una situación de legalización y el coste no es tan grande para la cantidad de problemas que nos podemos evitar.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
NO ESTARÍA MAL QUE OTROS TERTULIANOS NOS CONTARAN SUS EXPERIENCIAS Y OPINIONES O QUE TRABAS SE HAN ENCONTRADO.&lt;br /&gt;
&lt;br /&gt;
Un saludo a todos.&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Refrigeracion :: RE: Presion De Trabajo De Compresor Con R404a</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1490#p1490"/>
		<dc:creator>joseb65</dc:creator>
		<dc:subject>Refrigeracion</dc:subject>
		<author>
		<name>joseb65</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1490#p1490</id>
		<issued>2010-09-06T15:01:16Z</issued>
		<modified>2010-09-06T15:01:16Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=4&quot; target=&quot;_blank&quot;&gt;joseb65&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: Presion De Trabajo De Compresor Con R404a&lt;br /&gt;Publicado: Lunes, 06 Septiembre 2010, 03:01 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	hola jose ,ya se que lo pasaste mal, espero lo superes todo,yo por aqui  a ratos estamos preparando otro foro , el 2 ya  lo conoces, frio climatizacion y compresores, en esta pagina mira los compresores, las tablas, si necesitas mas ya sabes, que te mejores, lo mio poco a poco , pero que bamos  hacerle, un abrazo&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
  esto es l´UNITE HERMETICA si buscas mas entra hay mas en frio climatizacion y compresores&lt;br /&gt;
&lt;br /&gt;
  &lt;a class=&quot;post-url&quot; href=&quot;http://www.sudifri.com/sec_1/4_CO_MANEUROP_2009.pdf&quot; target=&quot;_blank&quot;&gt;http://www.sudifri.com/sec_1/4_CO_MANEUROP_2009.pdf&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Refrigeracion :: RE: Presion De Trabajo De Compresor Con R404a</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1489#p1489"/>
		<dc:creator>JOSE_CM</dc:creator>
		<dc:subject>Refrigeracion</dc:subject>
		<author>
		<name>JOSE_CM</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1489#p1489</id>
		<issued>2010-09-06T14:42:13Z</issued>
		<modified>2010-09-06T14:42:13Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=39&quot; target=&quot;_blank&quot;&gt;JOSE_CM&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: Presion De Trabajo De Compresor Con R404a&lt;br /&gt;Publicado: Lunes, 06 Septiembre 2010, 02:42 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	holo joseb me alegro mucho de verte ,espero que te encuentres bien jose,yo la verdad no ando muy bien de salud,y apenas he estado trabajando en este ultimo año,pues estoy haciendo  algunos trabajos a tronpicones cuando me veo que puedo,,en fin.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
 El tema de cambiar el compresor original  es porque esta gripado,esta hecho un taco,revise condensador y relec de arranque ,estan perfecto,en pocas palabras el compresor esta alimentado y me salta el clicxon,asi que 100x100 seguro es el compresor.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
y muchisimas gracias jose.&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
	<entry>
		<title mode="escaped">Refrigeracion :: RE: Presion De Trabajo De Compresor Con R404a</title>
		<link rel="alternate" type="text/html" href="http://www.webfrio.com/viewtopic.php?p=1488#p1488"/>
		<dc:creator>joseb65</dc:creator>
		<dc:subject>Refrigeracion</dc:subject>
		<author>
		<name>joseb65</name>
		</author>
		<id>http://www.webfrio.com/viewtopic.php?p=1488#p1488</id>
		<issued>2010-09-06T12:40:00Z</issued>
		<modified>2010-09-06T12:40:00Z</modified>
	<content type="text/html" mode="escaped">Autor: &lt;a href=&quot;http://www.webfrio.com/profile.php?mode=viewprofile&amp;amp;u=4&quot; target=&quot;_blank&quot;&gt;joseb65&lt;/a&gt;&lt;br /&gt;
	Asunto: Re: Presion De Trabajo De Compresor Con R404a&lt;br /&gt;Publicado: Lunes, 06 Septiembre 2010, 12:40 PM (GMT 0)&lt;br /&gt;&lt;br /&gt;&lt;div class="post-text"&gt;
	hola pepe cuanto tiempo, como estas, bueno camaras de congelados trabajan  de -15 a -20ºc&lt;br /&gt;
&lt;br /&gt;
 camaras iberna -20 ºc con r502 carga 1,8 kg esto es para tartas etc&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
   expositor gas 134a vitrina mostrador presion de trabajo  bar de presion1 1/2) de -5 a -10 ºc alimentos entre 0y 5 ºc&lt;br /&gt;
&lt;br /&gt;
  por que tienes que cambiar el compresor, que sea igual para baja temp, y misma potencia,la carga te la da el fabricante y el gas un equivalente si te falta algo estaremos por aqui, saludos&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
  jose en cuanto a la UPRI G HT  te falta una letra G  NO TE PREOCUPE ES UN MODELO O MARCA DE CREO QUE ES LA MARCA DE FRIGORIFICOS, ht es alemana&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
  r404a  a -20=2.2Bar  30psi      r507a  a -20 = misma presion    &lt;br /&gt;
&lt;br /&gt;
 -------------------------------------------------------&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
para javi hay dos escalas de presion temp L V = L presion o temp de liquido llamado punto de burbuja&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
   V = presion o temp de vapor llamado punto de rocio  &lt;br /&gt;
&lt;br /&gt;
       a una misma temp 2 presiones distintas, no se si te refieres a esto , saludos&lt;/div&gt;&lt;br /&gt;
	</content>
	</entry>
</feed><!-- Page generation time: 0.7232s (PHP: 62% - SQL: 38%) - SQL queries: 10 - Memory Usage: 8.586 Mb  - GZIP enabled -->